ANALYSIS OF ROTOR ASYMMETRY FAULT IN THREE-PHASE LINE START PERMANENT MAGNET SYNCHRONOUS MOTOR

Mahdi Karami, Norman Mariun, Mohd Zainal Abidin Ab Kadir, Mohd Amran Mohd Radzi, Norhisam Misron

DOI Number
https://doi.org/10.2298/FUEE2104483K
First page
483
Last page
498

Abstract


This article proposed a detection scheme for three-phase Line start permanent magnet synchronous motor (LSPMSM) under different levels of static eccentricity fault. Finite element method is used to simulate the healthy and faulty LSPMSM with different percentages of static eccentricity. An accurate laboratory test experiment is performed to evaluate the proposed index. Effects of loading condition on LSPMSM are also investigated. The fault related signatures in the stator current are identified and an effective index for LSPMSM is proposed. The simulation and experimental results indicate that the low frequency components are an effective index for detection of the static eccentricity in LSPMSM.


Keywords

Line start permanent magnet synchronous motor, static eccentricity, current signature analysis, finite element method, fault detection

Full Text:

PDF

References


V. Šarac, "Line-Start Synchronous Motor a Viable Alternative to Asynchronous Motor", Facta Univ., Series: Automat. Control Robot., vol. 19, pp. 39-58, July 2020.

M. Karami, N. Mariun, M. R. Mehrjou, M. Z. A. Ab Kadir, N. Misron and M. A. M. Radzi, "Diagnosis of Static Eccentricity Fault in Line Start Permanent Magnet Synchronous Motor", in IEEE Proceedings of International Conference on Power and Energy, December 2014, pp. 83-86.

M. Karami, N. Mariun, M. R. Mehrjou, M. Z. A. Ab Kadir, N. Misron and M. A. M. Radzi, "Static Eccentricity Fault Recognition in Three-Phase Line Start Permanent Magnet Synchronous Motor Using Finite Element Method", Math. Probl. Eng., vol. 2014, pp. 1-12, Nov. 2014.

A. Nochian, O. Mohd Tahir, S. Mualan and D. Rui, "Toward Sustainable Development of a Landfill: Landfill to Landscape or Landscape along with Landfll? A Review", Pertanika J. Soc. Sci. Humanit., vol. 27, no. 2, pp. 949-969, 2019.

M. Karami, N. Mariun, M. A. M. Radzi and G. Varamini, "Intelligent stability margin improvement using series and shunt controllers", Int. J. Appl. Power Eng. (IJAPE), vol. 10, no. 4, pp. 281-290, 2021.

F. Rahmani, M. S. Mashhadi, H. Gh. Lamouki, F. Asghari, H. Shokouhandeh and M. Amoozadeh, "Maximum Power Point Tracking–A Study of Photovoltaic Systems in Supplying Stand-Alone and Grid-Connected Electrical Loads", in IEEE Proceedings of International Conference on Applied and Theoretical Electricity, May 2021, pp. 1-6.

J. Faiz, T. Asefi and M. Azeem Khan, "Design of Dual Rotor Axial Flux Permanent Magnet Generators with Ferrite and Rare-Earth Magnets", Facta Univ. Series: Elec. Energ., vol. 33, pp. 553-569, 2020.

B. M. Ebrahimi and J. Faiz, B. N Araabi, "Pattern identification for eccentricity fault diagnosis in permanent magnet synchronous motors using stator current monitoring" IET Electric Power Applications, vol. 4, pp. 418–430, 2010.

M. Karami, N. B. Mariun, M. Z. A. Ab-Kadir, N. Misron and M. A. M. Radzi, "Motor Current Signature Analysis-based Noninvasive Recognition of Mixed Eccentricity Fault in Line Start Permanent Magnet Synchronous Motor", Electr. Power Compon. Syst., vol. 49, no. 1-2, pp. 133-145, June 2021.

I. Hussein, Z. Al-Hamouz, M. A. Abido and A. Milhem, "On the Mathematical Modeling of Line-Start Permanent Magnet Synchronous Motors under Static Eccentricity", Energies, vol. 11, pp. 1-17, Jan. 2018.

W. Le Roux, R. G. Harley and T. G. Habetler, "Detecting rotor faults in low power permanent magnet synchronous machines", IEEE Trans. Power Elec., vol. 22, pp. 322–328, Jan. 2007.

A. Barbour and W. T. Thomson, "Finite element study of rotor slot designs with respect to current monitoring for detecting static airgap eccentricity in squirrel-cage induction motors", In IAS ’97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting, 1997, vol. 1, pp. 112–119.

W. T. Thomson and A. Barbour, "On-line current monitoring and application of a finite element method to predict the level of static airgap eccentricity in three-phase induction motors", IEEE Trans. Energy Conv., vol. 13, pp. 347–357, Dec. 1998.

S. Nandi, S. Ahmed and H. Toliyat, "Detection of rotor slot and other eccentricity related harmonics in a three phase induction motor with different rotor cages", IEEE Trans. Energy Conv., vol. 16, pp. 253–260, Sep. 2001.

T. C. Ilamparithi and S. Nandi, "Detection of eccentricity faults in three-phase reluctance synchronous motor", IEEE Trans. Ind. Appl., vol. 48, pp. 1307–1317, May 2012.

W. Le Roux, R. G. Harley and T. G. Habetler, "Detecting rotor faults in low power permanent magnet synchronous machines", IEEE Trans. Power Elec., vol. 22, pp. 322–328, Jan. 2007.