AIR POLLUTION AND THE FILTRATION PROCESSING SYSTEMS FOR THE BITUMINOUS MATERIAL PLANTS
Abstract
It is known that particulate matters of different granulations are one of the most important air and environmental pollutants, in general. This paper presents a prototype system for filtering particulate matter from extinguishing gases of a bitumen preparation plant using a "jet pulse" method for filter bags cleaning. For such type of filter plant, due to technological reasons, there is the need to create a shock wave which is required for the cleaning of the filter bags. The shock wave is generated by electromagnetic valves, whereas the tactile of the valve is determined by special controller depending on the type of filter, bags and air pollution. The result obtained through the use of special types of controllers allows the life span of the electric fan and the prevention of their overheating and damage.
Keywords
Full Text:
PDFReferences
Regulation of limit values for emissions of air pollutants, Official Gazette of the Republic of Serbia No. 71/2010 and 6/2011;
D. Jovanović, S. Jovanović, M. Jovanović, S. Đukić, “Implementation of PIC controller in Air Purifying Systems”, Proceedings of the XII International Conference on systems, automatic control and measurements, SAUM, pp 128-131, 978-86-6125-11
Low for air protection ("Off. Gazette of RS", No. 36/09);
Daniel Vallero, “Fundamentals of air pollution”, 2014.
Chuck Hellebuyck, “Programming PIC Microcontrollers with PICBASIC”, A volume in Embedded Technology, 2003, pages 112-132
K. Ellithy, S. Said, O. Kahlout, “Design of power system stabilizers based on μ-controller for power system stability enhancement”, International Journal of Electrical Power & Energy Systems,Volume 63, December 2014, Pages 933-939
Tim Wilmshurst, “CHAPTER 12–Some PIC microcontroller advances”, Designing Embedded Systems with PIC Microcontrollers (Second Edition), 2010, pages 371-389.
V. Tasić, B. Maluckov, T. Apostolovski-Trujic, R. Kovačević, M. Živković, I. Lazović, “Particulate matter (PM10 and PM2.5) concentrations in naturally ventilated offices in Bor, Serbia”, Facta Universitatis, Series: „Working and Living Environmental Protection“ , Vol. 12, No3, 0354-804X (Print), ISSN 2406-0534 (online),
N. Živković, N. Mišić, M. Jovanović, “Comparative analysis of the concentration of ambient air pollutants determined by measuring and modeling”, Facta Universitatis, Series: „Working and Living Environmental Protection“ , Vol. 11, No2, 0354-804X (Print), ISSN 2406-0534 (online),
DOI: https://doi.org/10.22190/FUWLEP1702159J
Refbacks
- There are currently no refbacks.
ISSN 0354-804X (Print)
ISSN 2406-0534 (Online)