THE COMPARATIVE ANALYSIS OF THE RESULTS OF POLLUTANTS MEASUREMENTS IN AMBIENT AIR MEASURED WITH MEASURING STATIONS „AIRPOINTER“

Milena Jovanović, Nikola Mišić

DOI Number
-
First page
219
Last page
232

Abstract


Abstract: Measurements of pollutants in the ambient air are made with different devices and by using different methods. In order to determine the representativeness of the measurements results are performed inter-laboratory comparisons. This paper presents the results of an inter-laboratory test of NO, NO2, NOx, O3 and PM10 concentrations, which are measured by the automated measuring stations “Airpointer” at the measuring point city stadium “Sloboda" in Užice in the period of time: 11th to 17th February 2014.

Keywords: pollutants, measuring station "Airpointer", comparative analisys of the results


Full Text:

PDF

References


Law of Air Protection ("Off. Gazette of RS", No.36/2009)

Regulation of conditions and requirements for monitoring air quality ("Off. Gazette of RS", No.11/2010)

Instruction manual “Airpointer”, Recordum Messtechnik GmbH

Živković N., Đorđević A., Zaštita vazduha – teorijske osnove predviđanja zagađenosti vazduha, Fakultet zaštite na radu, Niš, 2001., ISBN 86-80261-32-7.

S.J. Welham, S.A. Gezan, S.J. Clark, A. Mead, Statistical Methods in Biology: Design and Analysis of Experiments and Regression.


Refbacks

  • There are currently no refbacks.


ISSN   0354-804X (Print)

ISSN   2406-0534 (Online)