Abstract


Staircases are very important from the point of view of fire protection. There are several reasons for this standpoint, but two are particularly significant. The first is that stairs are an important means of evacuation in multi-storey buildings, and the second is that the moment of detection of fire is crucial for the beginning of the evacuation. The first fact refers to the stair’s location in buildings and the dimensions of stairs and landings. The importance of the second fact is obvious – the location and numbers of fire detectors directly affect early fire detection, and consequently the beginning of evacuation. The worst-case fire scenario from the aspect of building design - a staircase in the center of the building - was chosen for the simulation described in the paper, because in Serbia, there are many structures like this For the simulation described in the paper, the worst-case fire scenario was selected from the aspect of building design - a staircase in the centre of the building, because there are many, such in our country. On the other hand, recommendations for the location and number of fire detectors on a staircase are different in world-leading standards. For these reasons, in this paper, the simulations were performed in an eight-story building for various dimensions of spaces between stairs. On the basis of a comparison of the regulations outlined in European, British, German, American, and Russian standards, simulation parameters are defined. Parameters for simulations are defined on the basis of a comparative analysis of rules stated in European, British, German, American and Russian standards. Taking into account that some emergency evacuations entail moving through smoke-filled areas, building engineers must understand how the aforementioned factors affect smoke development in the event of a fire, and thus effective evacuation.

Keywords

fire detection, multi-storey building, staircase, standards, simulation

Full Text:

PDF

References


EN 54 Fire detection and fire alarm system (2004), Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance.

DIN VDE 0833 Alarm systems for fire, intrusion and hold up (2009), Part 2: Requirements for fire alarm systems.

BS 5839 Fire detection and fire alarm system for buildings (2002), Part 1: Code of practice for design, installation and commissioning and maintenance of system in non-domestic premises.

NFPA 72 (2016), National Fire Alarm and Signaling Code, 2016 Edition.

СП 5.13130.2009 (2009) Системы противопожарной защиты. Установки пожарной сигнализации и пожаротушения автоматические. Нормы и правила проектирования.

Proulx, G. (2002) Movement of People: The Evacuation Timing, SFPE Handbook of Fire Protection Engineering, Third Edition, National Fire Protection Association.

Lei, Wenjun, Tai, Chuanmin (2019), Effect of different staircase and exit layouts on occupant evacuation, Safety Science 118 (2109) 258-263.




DOI: https://doi.org/10.22190/FUWLEP2301017B